What was found
LT FLOOR SILLS AND FRAME FLANGES AND ANGLES FS 424 TO FS 484 HAVE CORROSION IN NUMEROUS PLACES. AREAS PREVIOUSLY REPAIRED IAW REO 601R-53-41-302. REMOVED CORROSION IAW SRM 51-12-00. MATERIAL REMOVED IS BEYOND REPAIRABLE LIMITS IAW SRM REPAIR & IAW REO. REMOVED CORROSION IAW REO 601R-53-41-302. STEPS 2-5. C/W REO 601R-53-41-302A STEP 2 LPI BLENDED AREAS IAW NDTM 51-20-08. NO INDICATIONS NOTED AT THIS TIME. C/W REO 601R-53-41-302, STEP 3. C/W REO 601R-53-41-302 CORROSION REMOVAL, STEPS 4-5. ALL WORK PERFORMED IAW ECTC 601R-53-41-302.