What was found
LT FS 718.00 FRAME IS CRACKED BETWEEN STRINGER 10 AND 12. REMOVED LT FRAME AT FS 718.00 IAW SRM 51-42-06. UPON REMOVAL OF FRAME, LOWER SPLICE PLATE WAS DAMAGED (BENT), REQUIRES REPLACEMENT. FABRICATED NEW LOWER SPLICE PLATE IAW DRAWING 600-36030 AND SRM 51-24-16. INSTALLED LT 718 FRAME TO ACFT STRUCTURE AND UPPER AND LOWER SPLICE PLATES IAW SRM 51-42-06. ALL GROUND WIRES, ACM STRUCTURE MOUNTING BOLTS, AND WIRE BUNDLES THAT WERE REMOVED FOR 718 FRAME ACCESS REQUIRE REINSTALLATION. INSTALLED ALL GROUND WIRES AND MOUNTING BOLTS AND WIRE BUNDLES IAW SRM 51-41-00 AND 51-41-02 AND AMM 51-80-00-400-804. PAINTED LT FS 718 FRAME IAW SRM 51-25-01.S 718.00 FRAME IS CRACKED BETWEEN STRINGER 10 AND 12.