What was found
2 INDICATIONS NOTED ON FWD SIDE OF FS 621.0 PRESSURE BULKHEAD WEB, ABOVE AND BELOW LINTEL FITTING. INDICATION ABOVE FITTING IS APPROX .2" IN LENGTH AT 80% F.S.H. INDICATION BELOW FITTING IS APPROX .2" IN LENGTH AT 100% F.S.H. FAILED NDT INSPECTION. REPAIR PER EC/TC REO 601R-53-61-1230 HAS BEEN COMPLETED AND THE REPAIR COMPLIES WITH THE REQUIREMENTS OF EC/TC AND REO 601R-53-61-1230 REV D. FUSELAGE EXTERIOR REQUIRES PAINT. TOUCHED UP RIVETS IAW SRM 51-25-01.