What was found
LT FS 484 FLOOR SUPPORT INTERCOSTAL ANGLE AT O/B SIDE LBL 9 CRACKED .2" LONG. REMOVED CRACKED FS 484 FLOOR SUPPORT ANGLE AT O/B LBL 9. LOCATED NEW SERVICEABLE ANGLE. INSTALLED 4 EA RIVET THROUGH INTERCOSTAL IAW SRM 51-42-06. FOUR EA FASTENERS THROUGH FLOORBEAM REQUIRE INSTALL. INSTALLED 4 FASTENERS THRU FLOORBEAM IAW REO 601R-53-41-949. C/W EO EC/TC REO 601R-53-41-949 REV 0 REO 601R-53-41-949 REV D DATED 5/20/09.