What was found
FS 409.0+128 VERTICAL POST LBL 18.0 HAS INDICATION NOTED AT O/B SIDE WL 69.0 AFT FLANGE APPROX .2 INCH IN LENGTH 50 PERCENT FSH FAILED NDT INSP. REMOVED VERTICAL POST LBL 18 FS 409 + 128 IAW SRM 51-42-06. FABRICATED NEW VERTICAL POST AT LBL 18.0 FS 409.0 + 128 USING 7075.0 .063 PO 104964/1 AS PER SAMPLE IAW SRM 51-24-16 REF DWG 601R32208. HEAT TREATED, FABRICATED NEW VERTICAL POST FROM 7075-0 .071 TO T62 CONDITION IAW AMS 2770. PAINTED IAW SRM 51-25-16. LOCATED, DRILLED & RIVETED INBOARD & OUTBOARD POSTS IAW SRM 51-42-06. INSTALLED VERTICAL POST AT LBL 18.0 FS 409 + 128 IAW REO 601R-53-41-889 AND SRM 51-42-06 & 51-42-22. C/W AS EC/TC REO 601R-53-41-889 AND MET ALL THE REQUIREMENTS OF REO 601R-53-41-889.