FIVE (5EA) RIVNUTS ON FLOORBEAM FS 559+4 AND FS 559+64 NEED REPLACED IAW SRM 51-42-34 RBL 9. UPON INVESTIGATION, FOUND FASTENERS TO BE BLIND NUTS NOT RIVNUTS. REPLACE 6 EACH BLIND NUTS. DRILLED 6 EACH AND REMOVED PER SRM 51-42-34. INSTALLED 6 NEW BLIND NUTS IAW SRM 51-42-34 BETWEEN FS 559+50 TO 559+64.