What was found
CARGO BAY FLOORBEAM AT LBL 27 IS CORRODED AROUND FLOORBOARD ATTACH FLANGES FROM FS 574 TO FS 621. REMOVED FLOORBEAM CAP IAW SRM 51-42-06, 51-42-21. INSTALLED NUT PLATES IAW SRM 51-40-11 AND 51-42-06. INSTALLED FLOORBEAM CAP PER SRM 51-42-21 AND 51-42-34. COMPLIED WITH EC/TC REO 601R-53-61-3278 AND MET REQUIREMENTS OF REO 601R-53-61-3278.