What was found
DURING 6 YEAR INSPECTION IAW TC 53-900-500, FOUND CORROSION OF RIGHT LOWER WEB STRUCTURE AT FS 280.00. REMOVED AND REPLACED RT LOWER WEB STRUCTURE AT FS 280 IAW CRJ 700 SRM 53-11-10 TASK 53-11-10-201-003-A01. BLENDED CORROSION IAW SRM 51-12-00 AND FOUND TO BE OUT OF LIMITS REF SRM 53-11-10 REPAIR 003-A01. REMOVED WEB IAW SRM 51-42-06.LOCATED HOLES IN NEW WEB OF BULKHEAD PN 670-53-11-52-2 IAW SRM 51-42-06, 51-42-13 AND 53-11-10 INSTALLED WEB IAW SRM 51-42-06 AND 51-42-11.