What was found
MAIN CABIN AT LBL 43.00 BETWEEN FS 513.00 & FS 529.00 HAS 1 EA FASTENERS HOLE ON UPPER SURFACE OF PRESSURE SILL STRUCTURE WITH CRACK EXTENDING FROM NUTPLATE ATTACH FASTENER HOLE TO FASTENER HOLE WITH CORROSION INSIDE CRACK. REPAIRED MAIN CABIN AT LBL 43.00 BETWEEN FS 513.00 TO FS 529.00 FASTENER HOLE ON UPPER SURFACE OF PRESSURE SILL STRUCTURE IAW REO 601R-53-41-1074. COMPLIED WITH EC/TC REO 601R-53-41-1074 IAW REO 601R-53-41-1074.