What was found
CORROSION ON FRAME AT FS 319.70 AND STR 27 IN BELLY OF ACFT IN AVIONICS BAY. REMOVED AND REPLACED FRAME SEGMENT AT FS319.70 BETWEEN STRINGERS 23L AND 23R AND SEALED, RESTORED A023 FINISH, THEN CIC WAS APPLIED. ALL WORK DONE IAW SRM'S 51-21-11, 51-21-16, 51-23-00, 51-41-00 AND 51-42-06.