What was found
FS 280.00 TRANSVERSE FLOORBEAM CRACKED AT THE RT FLOORBEAM MEMBER AT RBL-9 AT LWR FLANGE RADIUS. CUT OUT DAMAGED AREA AND REMOVED EXISTING FASTENERS IN REPAIR AREA. REMOVED EXISTING -5 CLIP AT FS280 RBL 9 PER REO 601R-53-11-171. PERFORMED ET INSP FOLLOWED BY FPI OF CUTLINE IAW NDTM 51-20-06/08. RECEIVED CRACK INDICATION AT LOWER CUTLINE AROUND THE LWR FASTNER HOLES. STARTED FABRICATING NEW -5 CLIP FROM S 6144-14 BATCH 1085294 AND -4 REPAIR ANGLE FROM 7075-T6 .050 BATCH 1066537 IAW REO 601R-53-11-171. FINISHED FABRICATING -5 CLIP AND REPAIR ANGLE AND FABRICATED -6 FILLER AND -8 FILLER PER REO 601R-53-11-171. OPENED CUT OUT IAW SCHEME B REO 601R-53-11-171. PERFORMED ET INSP OF CUTLINE FS 280, RBL 9.0 IAW REO 601R-53-11-171 IAW NDTM 51-20-06 NO DEFECTS NOTED. PERFORMED LPI OF -8 FILLER IAW NDTM 51-20-08. NO DEFECTS NOTED. PARTIALLY INSTALLED -4 DOUBLER, -8 FILLER IS COMPLETELY INSTALLED WORK DONE IAW SRM 51-42-06 AND REO 601R-53-11-171. INSTALLED REMAINING FASTENERS (HI LITES) IN REPAIR IAW REO 601R-53-11-171 AND SRM 51-42-21. APPLIED A023 FINISH AND CIC IAW SRM 51-21-16. WORK COMPLETE.