What was found
FOUND REAR PRESSURE BULKHEAD WEB THAT SURROUNDS THE LINTEL ATTACHMENT FITTING HAS INDICATION NOTED APPROX .2" IN LENGTH 90 PERCENT FSH. FAILED NDT INSPECTION. REPAIR IAW REO 601R-53-61-1230 HAS BEEN COMPLIED AND THE REPAIR COMPLIES WITH THE REQUIREMENTS OF EC/TC AND REO 601R-53-61-1230 REV D. REPAIR REQUIRES PAINT & SEAL. APPLIED AERODYNAMIC SEALANT TO REPAIRED AREA IAW AMM 51-23-00-390-809 PART 2 THRU D AND 3A1&2. ALSO PAINTED REPAIRED AREA IAW SRM 51-25-01 STEP 8A NR 3 & 8B1 A THRU G.