What was found
MAIN CABIN BETWEEN FS 409+128 & FS 559.00 PRESSURE FLOOR SILL FINGER WEB DOUBLER HAS NUMEROUS AREAS OF CORROSION ON LT SIDE. REMOVED CORROSION FROM PRESSURE FLOOR SILL FINGER DOUBLER IAW REO 601R-53-41-666 AND SRM 51-21-06. COMPLIED WITH REO 601R-53-41-666A. PERFORMED EDDY CURRENT OF REPAIRED AREAS LT SIDE PRESSURE FLOOR SILL DOUBLER IAW NDTM 51-20-06. NO INDICATIONS NOTED AT THIS TIME. RESTORED FINISH OF REPAIRED AREA IAW ITEM 13 OF REO 601R-53-41-666. RESTORED SEALANT BEAD TO REPAIRED AREA IAW ITEM 14 OF REO 601R-53-41-666. APPLIED CORROSION INHIBITING COMPOUND TO REPAIRED AREA IAW ITEM 15 OF REO 601R-53-41-666.