What was found
MAIN CABIN LT SIDE BETWEEN FS 409+128 & FS 559.00 PRESSURE FLOOR SILL WEB HAS NUMEROUS AREAS OF CORROSION. REMOVED CORROSION FROM PRESSURE FLOOR SILL WEB IAW REO 601R-53-41-666 & SRM 51-21-06. COMPLIED WITH REO 601R-53-41-666A. PERFORMED EDDY CURRENT OF REPAIRED AREAS IAW NDTM 51-20-06. NO INDICATIONS NOTED AT THIS TIME. RESTORED FINISH TO REPAIRED AREA IAW ITEM 6 OF REO 601R-53-41-666. RESTORED SEALANT BEAD ALONG SEAL EDGE IAW ITEM 7 OF REO 601R-53-41-666. APPLIED CORROSION INHIBITING COMPOUND TO REPAIRED AREA IAW ITEM 8 OF REO 601R-41-666. COMPLIED WITH REO 601R-53-41-666 REV O DATED 27 MAY, 2008.