What was found
MAIN CABIN RT SIDE BETWEEN FS 409+128 & FS 559.00 PRESSURE FLOOR SILL WEB HAS NUMEROUS AREAS OF CORROSION. REMOVED CORROSION FROM PRESSURE FLOOR SILL WEB IAW REO 601R-53-41-666 AND SRM 51-21-06. COMPLIED WITH REO 601R-53-41-666A. PERFORMED EDDY CURRENT OF REPAIRED AREA OF RT SIDE PRESSURE FLOOR SILL IAW NDTM 51-20-06. NO INDICATIONS NOTED AT THIS TIME. RESTORED FINISH OF REPAIRED AREAS IAW ITEM 6 OF REO 601R-53-41-666. RESTORED SEALANT ALONG SILL IAW STEP 7 OF REO 601R-53-41-666. APPLIED CORROSION INHIBITING COMPOUND IAW ITEM 8 OF REO 601R-53-41-666. COMPLIED WITH REO 601R-53-41-666 REV O DATED 27 MAY, 2008.