What was found
FOUND FS 409+128 VERT POST BL 0.0 LT SIDE HAS INDICATION NOTED APPROX .2" IN LENGTH 60 % FSH AFT FLANGE RADIUS. FAILED NDT INSP. DISCONNECTED AIR DUCTS IAW SRM 51-41-02 FOR ACCESS TO POST. REMOVED POST IAW SRM 51-42-06. LOCATED, DRILLED AND ASSEMBLED POST IAW SRM 51-40-11 AND 51-42-06. INSTALLED POST ASSY LT REINFORCEMENT ANGLE AND AIR DUCTS. INSTALLED POST ASSY IAW SRM 51-42-06 AND REO 601R-53-41-1160. FILLET SEAL POST ASSY TOUCH-UP PAINT AREA. LOCATED AND INSTALL LT REINFORCEMENT ANGLE AND INSTALL AIR DUCTS. INSTALLED REINFORCEMENT ANGLE IAW SRM 51-42-06 AND REO 601R-53-41-1160. FILLET SEALED POST IAW SRM 51-23-00 & RESTORED PAINT FINISH IAW STILL REQUIRES AIR DUCT INSTALL.