What was found
FLOOR SUPPORT ANGLE HAS CORROSION AROUND NUTPLATE HOLES AT FS 559.00 BETWEEN LBL 9 AND LBL 27. FOUND CORROSION TO BE BEYOND LIMITS. REMOVED FLOOR SUPPORT ANGLE CAP IAW SRM 51-42-06 STEP 11 AND 51-42-29 STEP 11. INSTALLED NEW SERVICEABLE FLOOR SUPPORT ANGLE CAP IAW SRM 51-42-06 STEPS 1 AND 9. PAINTED IAW SRM 51-25-01.