What was found
FS 559.00+80 - FS 621.00 RT FLOOR SILL HAS CORROSION. REMOVED NUTPLATES FROM RT CARGO SILL PLATE IAW SRM 51-42-15 STEP 10 AND 51-42-10 FIGURE 4. REMOVED CORROSION FROM RT CARGO SILL IAW SRM 51-21-06 STEP 3. INSTALLED NEW NUTPLATES IAW SRM 51-45-00 STEP 9 AND 51-42-15 STEP 6. RT CARGO FLOOR SILL HAS CORROSION REMAINING. REMOVED CARGO FLOOR SILL IAW SRM 51-42-06 AND 51-42-21. INSTALLED DOUBLERS AND NUTPLATES IAW SRM 51-42-06. INSTALLED GROMMETS IAW SRM 51-22-00. INSTALLED CABLE SUPPORT IAW SRM 51-42-13. INSTALLED SERVICEABLE CARGO SILL PLATE IAW SRM 51-42-21 AND SRM 51-42-06. APPLIED PROTECTIVE TOPCOAT IAW SRM 51-25-16.