As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FS 310 AT SERVICE DOOR ON SPLICE PLATE. REMOVED SILL PLATE JUST FWD OF SERVICE DOOR CUTOUT IAW SRM 51-42-06, TO ACCESS SPLICE PLATE. LOCATED & DRILLED NEW SPLICE PLATE IAW SRM 51-40-11 & INSTALLED IAW SRM 51-42-21. SILL PLATE REQUIRES INSTALLED. INSTALLED SILL PLATE FWD OF SERVICE DOOR AT WL 73 IAW SRM 51-42-06 & 51-42-21 FS 295.0 - 310.0.