What was found
CORROSION ON FS 349.00 FRAME TO ATTACHMENT FLANGE BETWEEN STR 26L - STR 26R. (3 PLACES). REMOVED FRAME IAW SRM 51-42-06 STEPS A, B1 THROUGH 6 AND SRM 51-42-21 STEPS 11A1 AND B1. LOCATED AND DRILLED NEW FRAME SECTOR IAW AMM 51-42-06. INSTALLED NEW FRAME SECTOR P/N 601R3200569 IAW SRM 51-42-06 STEP 1,2,5,8, 9 & 10 AND SRM 51-42-21 STEP 1 THRU 6, 9 AND 10 IAW SRM 51-42-06 STEPS 1,4,5,7,8-10.