What was found
FLOOR SUPPORT SILL ON RT SIDE APPROX RBL 49 FROM FS 574 TO 621 HAS CORROSION AROUND NUTPLATE LOCATION. REMOVED NUTPLATES (10) FROM FLOOR SUPPORT IAW CRJ SRM 51-42-10 FIGURE 4. BLENDED AREA REMOVING CORROSION IAW CRJ SRM 51-21-06 STEP 6A. PRIMED AND PAINTED IAW CRJ SRM 51-21-06 STEP 6 A(1)(D).