What was found
FS 409+128 BL 0.00 VERT POST FAILS NDT WITH AN INDICATION IN AFT RT "C" CHANNEL. (GREATER THAN 50 PERCENT SCREEN HEIGHT). REMOVED POST IAW SRM 51-42-06. POST LOCATED & DRILLED INBD & OTBD POST HOLES IAW SRM 51-40-11. INSTALLED INBD & OTBD POST HOLES TOGETHER, IAW SRM 51-42-06. INSTALLED POST BL0, IAW REO 601R-53-41-889. INSTALLED NEW SERVICEABLE INBD & OTBD POST ANGLES AT BL0, IAW SRM 51-42-06/REO 601R-53-41-889. C/W EC/TC REO 601R-53-41-889 & MET ALL THE REQUIREMENTS OF REO 601R-53-41-889.