What was found
FS 559.0 BULKHEAD WEB & CAP ANGLE HAS (5) HFEL INDICATIONS NOTED AS LISTED: (1) IN WEB 70 PERCENT FSH 0.5" LONG AT RBL 18.0 WL 59.10 (2) IN WEB 60% FSH0.5" LONG AT RBL 9.0 WL 54.10 (3) IN CAP ANGLE 60 PERCENT FSH 0.2" LONG BELOW RBL 18.0 POST (4) IN CAP ANGLE 50 PERCENT FSH 0.2" LONG BELOW LBL 18.0 POST (5) IN CAP ANGLE 50 PERCENT FSH 0.2" LONG BELOW LBL 9.0 POST. FAILS NDT INSPECTION. COMPLIED WITH EC/TC REO 601R-53-41-260 IAW REO 601R-53-41-260.