What was found
ON INSP, FOUND 280 BEAM TO BE CORRODED OUT OF LIMITS. EO 700-53-0061 ITEM 3 CUT OUT DAMAGED 280 LT AND RT BEAM SECTIONS. REMOVED FS 280 FLOORBEAM FASTENERS IAW SRM 51-42-06 AND 51-42-21 TO COMPLETELY REMOVE DAMAGED BEAM SECTIONS FOR REPLACEMENT. CUT FLOORBEAM AS SHOWN IN REO 670-53-11-047 PER NOTE 1. IAW NOTE 2 OF REO 670-53-11-047 AND EO 700-53-0061 ITEM 4, PERFORMED ET INSP OF CUT LINE ON FLOORBEAM IAW REO670-53-11-047 AND EO700-53-0061 IAW NDTM PART 1, 51-20-006. NO INDICATED NOTED AT THIS TIME. -2 & -3 FABRICATED DOUBLERS REQUIRED IAW NDTM PART 1, 51-20-006 OR PART 1,