Service difficulty report · Door · Cndair CL6002B19

Difficulty date
March 23, 2010
Submitted
March 26, 2010
Operation
Air carrier
Aircraft
N825AS
Make and model
Cndair CL6002B19
Aircraft serial
7207
Aircraft time
28,505 hours, 25,462 cycles
Engine
Ge CF343B1
Part
Door
Condition
Out Of Adjust
Location
Emergency Exit
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT OVERWING EMERGENCY EXIT FAILED FUNCTIONAL TEST. ADJUSTED RT OVERWING EMERGENCY EXIT IAW AMM 52-21-00-820-801. RT OVERWING EMER EXIT FUNCTIONAL TEST GOOD IAW AMM 52-21-00-720-801. STESP 4A(4-6) ON AMM 52-21-00-720-801. PRESSURIZED ACFT IAW MM 21-32-00-863-801. LEAK CHECK OF RT OVERWING LINER EXIT GOOD AT THIS TIME. SYS WORKING PROPERLY.