Service difficulty report · Line · Cndair CL6002B19

Difficulty date
March 11, 2010
Submitted
March 31, 2010
Operation
Air carrier
Aircraft
N823AS
Make and model
Cndair CL6002B19
Aircraft serial
7196
Aircraft time
28,866 hours, 25,834 cycles
Engine
Ge CF343B1
Part
Line
Condition
Leaking
Location
Nr 1 Hyd Pump
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SHORTLY AFTER TAKEOFF "HYD 1 LO PRESS" NOTED. PRESSURE FLUCTUATED 2100-2300 PSI. RAN QRH WITH PUMP IB ON PRESSURE DROPPED BELOW 1800 PSI AND CONTINUED TO FLUCTUATE. NO QUANTITY REDOUT FOR HYD NR 1 ON SYNOPTIC. SHUTDOWN NR 1 ENG AFTER LDG 32 MIN LATER. (ACFT RETURNED TO DEPARTURE AFTER T/O -- EMERGENCY DECLARED) REPAIRED NR 1 EDP SUCTION LINE IAW AMM TASK 20-22-00-910-802. LEAK CHECK GOOD.