What was found
FOUND FS 409.0+128 VERTICAL POST LBL18 OTBD SIDE HAS INDICATION NOTED APPROX .2" IN LENGTH 70 PERCENT FSH BOTH FAILED NDT INSP AT WL69. AFT FLANGE RADIUS. REMOVED LBL 18 FS 409+12 VERTICAL POST ASSY IAW IAW SRM 51-42-06. REQUIRES LOCATION & INSTALLED. LOCATED & DRILLED 409+128 LBL 18 POST IAW SRM 51-40-11. POST REQUIRES INSTALL. OK TO INSTALL. INSTALLED 409+128 POST AT LBL 18 IAW SRM 51-42-06 STEP 9 & C/W EC/TC REO 601R-53-41-889 AND MET ALL THE REQUIREMENTS OF REO 601R-53-41-889. PAINTED POST IAW SRM 51-25-01 PROCEDURE 8 STEP B1,A,B,C,D,E,F AND G. IAW SRM 51-21-01 PROCEDURE 3 STEP A-1,2 AND 3.