What was found
AVIONICS COMPARTMENT FS 333.00 FRAME HAS CORROSION. REMOVED CORRODED FRAME AND LT VERTICAL POST AT FS 333.00, LOCATED FASTENER HOLES IN NEW FRAME IAW SRM 51-42-06, 51-42-21 AND 51-40-11. INSTALLED FRAME AT FS 333.00 FROM STR 23L - 23R AND VERTICAL POST AT STR 23L IAW SRM 51-42-06 & 51-41-21. FRAME REQUIRES PAINT & CORROSION PREVENTITIVE. INSTALLED GROUND STUDS IAW SRM 51-41-04. BOND TEST IAW AMM 51-80-00-760-802 IS GOOD.