As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME SECTION AT FS 333 FOUND CORRODED AT APPROX RBL 9 AT GROUND STUD ATTATCH POINTS, ONE GROUND STUD CORRODED OUT OF FRAME. (RESOLVED ON W/O: 155601 TASKCARD: N/R-00318 ) JOB 8732425/ OPERATION 135/ REMOVED UNSERVICABLE FRAME FROM FS 333 AND INSTALLED SERVICEABLE FRAME AT FS 333 ALL WORK DONE IAW SRM 51-42-06 AND SRM 51-42-21. (CLOSED)