What was found
CORROSION FOUND ON STR 26R 3" AFT OF FS 333. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00. STARTED SPLICE REPAIR FOR STRG 26R IAW SRM 53-00-03. PERFORMED ET INSPECTION OF CUT LINES IAW SRM 53-00-03 PARA.4.(5) IAW NDTM PART 1, 51-20-06. NO INDICATIONS NOTED. CONT WITH STEP 9 OF SRM 53-00-03, PGE 204. COMPLIED WITH STEP 9 OF SRM 53-00-03 INSTALLED ALL FASTENERS EXCEPT FOR FASTENERS THAT ATTACH SPLICES. CONT. WITH STEP 10 OF SRM 53-00-03, PAGE 204. ATTACHED AFT SPLICE ON STAGE 26R ALL WORK DONE IAW SRM 53-00-03. INSTALLED FWD SPLICE ONSTR 26R AND APPLIED PROTECTIVE COATING IAW SRM 53-00-03 AND SRM 51-25-01.