What was found
CORROSION FOUND ON RT LONGITUDINAL FLOORBEAM AT RBL9.0 BETWEEN FS581.00 & 684.00. CORROSION ON FLOORBEAM AT RBL9 BETWEEN FS581.00 & 684.00. REMOVED IAW SRM 51-21-06. UT THICKNESS TEST REF NDTM 51-20-004. THICKNESS READINGS RANGED .059-.124" IN BLEND. DAMAGE AT FS581.00 OUT OF LIMITS IAW SRM 53-31-43-101-001-A01. SPLICE REPAIR DUE; TRANSFERED WORK 7105725/76. DAMAGE AT FS684.00 WITHIN LIMITS IAW SRM 53-31-43-101-001-A01. RESTORED FINISH IAW A023 OD SRM 51-21-16-001-001-A01.