What was found
FLOOR SUPPORT CLIPS CRACKED AT FS 280, LBL 9, INBD AND OTBD. REMOVED CLIPS AT FS 280, LBL 9, INBD AND OTBD FOR REPLACEMENT IAW SRM 51-42-21. LOCATE, DRILL AND INSTALL NEW CLIPS. LOCATED AND DRILLED NEW CLIPS FOR FS 280, LBL 9 FLOOR SUPPORT IAW SRM 51-40-11. INSTALL CLIPS. INSTALLED 2EA SERVICEABLE CLIPS IN CONJUNCTION WITH MWC 8742111 OP 154.