Service difficulty report · Floor Support · Cndair CL6002B19

Difficulty date
May 3, 2010
Submitted
May 7, 2010
Operation
Air carrier
Aircraft
N929EV
Make and model
Cndair CL6002B19
Aircraft serial
8007
Aircraft time
12,875 hours, 11,147 cycles
Part
Floor Support
Condition
Corroded
Location
Bs 319-330
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT FLOOR EDGE MEMBER FWD OF SERVICE DOOR FS 319 TO 330 HAS CORROSION. CORROSION MEASURES .004 AT DEEPEST POINT. THIS IS WITHIN REPAIRABLE LIMITS IAW SRM 53-21-43 AND 53-00-00. REMOVED CORROSION IAW SRM 51-21-06 LIGHT AND MODERATE CORROSION REMOVAL. REMOVED FLOOR EDGE MEMBER TO ACCESS CORROSION. REINSTALLED SAME SERVICEABLE FLOOR EDGE MEMBER IAW SRM 51-42-06.