As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BULKHEAD FITTING ON FLOORBEAM CAP RBL 9 AT FS 621 CORRODED. REMOVED BULKHEAD FITTING ON FLOORBEAM CAP IAW SRM 51-42-21. DRILLED AND LOCATED NEW SERVICEABLE FITTING IAW SRM 51-40-11. INSTALLED FITTING AT FLOORBEAM CAP IAW SRM 51-41-02 AND REO 601R-53-61-3679. COMPLETED IAW REO 601R-53-61-3679 AND MEETS ALL ITS REQUIREMENTS.