What was found
FLOOR SUPPORT STRUCTURE IS CRACKED FS 280 AT RBL 9.0, WEB AND CLIP. REMOVED I/B AND O/B RBL 9.0 FS 280 CLIPS IAW SRM 51-42-06 AND 51-42-21. REPLACED I/B CLIP RBL 9.0 WITH NEW SERVICEABLE CLIP IAW SRM 51-42-06 AND 51-42-21. PERFORMED NDT PER NDTM 51-20-06. NO INDICATIONS NOTED. COMPLIED WITH EC/TC 601R-53-11-171 AND MET ALL THE REQUIREMENTS OF REO 601R-53-11-171. REPLACED O/B CLIP IAW REPAIR REO 601R-53-11-171.