What was found
TWO INDICATIONS FOUND DURING INSP OF FS 409.0+128 VERTICAL POST AT RBL 18.0 1 ON I/B CHANNEL APPROX .312" LONG 100% FSH, 1 ON O/B CHANNEL APPROX .20" LONG 70% FSH FAILED NDT INSP. REMOVED VERTICAL POST AT F.S. 409+128 RBL 18 IAW SRM 51-42-06, 51-41-02. DRILLED/LOCATED NEW POST TOP ACFT IAW SRM 51-42-06. INSTALLED I/B AND O/B VERTICAL POSTS IAW SRM 51-42-06, 51-41-02 AND C/W EC/TC REO 601R-53-41-889 AND MET ALL THE REQUIREMENTS OF REO 601-R53-41-889 REV A. PRIMED, PAINTED, SEALED, AND APPLIED CORROSION INHIBITOR IAW SRM 51-25-06, 51-25-16, 51-23-00, AND 51-21-11.