What was found
NR 1 EMERGENCY CEILING FLOOD LIGHT CONNECTOR P355 (STN 409 RT) HAS A BROKEN WIRE. STRIPPED WIRE OF CONNECTOR P355 AND CRIMPED NEW CONTACT PN 350689-7 ON WIRE AND REINSERTED WIRE IN 9355 IAW ESPM CH 20-11-00-AND CH 20-16-00. PERFORM OPS TEST OF THE EMERGENCY LIGHTS IAW AMM 33-51-00-710-801. PERFORMED OPS TEST OF THE EMERGENCY LIGHT IAW AMM 33-51-00-710-801-A01. OPS CHECK GOOD AT THIS TIME.