What was found
CORROSION FOUND AT FS 333 BETWEEN STR 26L AND 27 FOUND ON FRAME. REMOVED CORROSION FROM FRAME BETWEEN STR 26L AND 26R IAW SRM 51-21-06. AT FS 333. PERFORMED THICKNESS INSPECTION OF BLEND AREA ON ANGLE AT FS 333.00 BETWEEN S26 AND S27L IAW MAC NDT INSP PROCEDURE UT-3 MINIMUM MATERIAL REMAINING IS .047". FRAME SECTOR NOMINAL THICKNESS IS .050. REMOVED DAMAGE IS LESS THAN 10 PERCENT. WITHIN SERVICABLE LIMITS IAW SRM 53-21-15 & 53-00-00. INSTALLED FASTENERS AND APPLIED A023 TOP COAT FINISH IAW B/P 601R31022 REV B.