What was found
FLOORBEAM CAP AT RBL 9, FS 621 TO FS 605 HAS MINOR CORROSION. REMOVED CORROSION ON FLOORBEAM CAP AT RBL 9 BETWEEN FS 605 AND FS 621 IAW SRM 51-21-06. CORROSION FOUND TO BE OUT OF REPAIRABLE LIMITS AND FLOORBEAM CAP REQUIRES REPLACEMENT. REPLACE FLOORBEAM CAP AT RBL 9 BETWEEN FS 569 AND FS 621. REMOVED FLOORBEAM CAP AT RBL 9 BETWEEN FS 569 AND FS 621 IAW SRM 51-42-06 AND SRM 51-42-21. FLOORBEAM CAP AT RBL 9 BETWEEN FS 569 AND FS 621 NEEDS DRILLED AND INSTALLED. INSTALLED NUTPLATES ON FLOORBEAM CAP IAW SRM 51-45-00 AND SRM 51-42-06. LOCATED AND INSTALLED BLIND NUTS ON FLOORBEAM CAP RBL 9 IAW SRM 51-42-34. FLOORBEAM CAP AT RBL 9 BETWEEN FS 569 AND FS 621 NEEDS DRILLED TO ACFT AND INSTALLED.