What was found
FS 280.00, BULKHEAD RT SIDE LOWER WEB HAS CORROSION DAMAGE. REMOVED BULKHEAD LOWER IAW SRM 51-42-06-001-001-A01. FABRICATED LOWER WEB IAW REO 670-53-11-052. FABRICATED WEB PANEL. PERFORMED LPI, TYPE 1, METHOD C ON RT LOWER WEB IAW SRM 51-12-00-001-001 IAW MAC NDT INSPECTION PROCEDURE PT-1. NO INDICATIONS NOTED AT THIS TIME. TRIMMED AND DRILLED ALL HOLES IN RT SIDE FABRICATED WEB IAW REO 670-53-11-052, INSTALLED FASTENERS IN WEB IAW REO 670-53-11-052. COMPLIED WITH EO 700-53-006201 REPAIR 2, WEB REPLACEMENT.