What was found
INDICATION NOTES AT FS 409+128 RBL 18 WL 69.0 IN RADIUS OF OTBD U CHANNEL OF THE BULKHEAD BEAM APPROX .30" LONG 50 PERCENT FULL SCREEN HEIGHT. REMOVED RBL 18 VERTICAL POST ASSY & SEPARATED INBD & OTBD HALVES IAW SRM 51-42-06. LOCATED & DRILLED NEW SERVICEABLE POST IAW SRM CH 51-40-11 & SUB ASSY INBD & OTBD POST HALVES IAW SRM CH 51-42-06. INSTALLED SERVICEABLE POST ASSY IAW SRM 51-42-06 & REO 610R-53-41-889. C/W EC/TC REO 601R-53-41-889 & MET ALL THE REQUIREMENTS OF REO 610R-53-41-889 REV A.