What was found
RIGHT FUSELAGE FLOOR SUPPORT SILL AT LBL 36 FASTENER HOLES HAVE CORROSION FROM FS 589 TO 559+112. AFTER CLEANING AREA FOUND NO CORROSION. RETREATED AREA IAW SRM 51-21-11. REMOVED FLOOR SILL IAW SRM 51-42-06 AND 51-42-21. FABRICATED REPLACEMENT LIPPED PLATE FOR SILL USING 7075-0 .050" IAW SRM 51-24-21. LOCATED AND DRILLED LIP PLATE AND SILL WEB IAW SRM 51-42-06, 51-42-21. TREATED, PRIMED AND PAINTED LIP PLATE IAW SRM CH 51-25-16. REPAIRED SILL WEB IAW REO 601R-53-51-119 STEPS 1-8.