As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CARGO COMPARTMENT BETWEEN FS 605.00 AND FS 621.00, RBL 43.00 FLOOR SUPPORT STRUCTURE AROUND FASTNER HOLES HAS CORROSION. BLENDED CORROSION ON FLOOR SILL BETWEEN FS 605.00 AND FS 621.00 RBL 43.00 IAW SRM CH 51-21-06. PERFORMED LPT THICKNESS MEASUREMENT OF BLENDED AREAS ON FLOOR SILL IAW MAC NDT INSP PROCEDURE UT-3. MINIMUM MATERAL REMAINING IS .046". PERFORMED EDDY CURRENT INSP IAW NDTM 51-20-06 AND REO 601R-53-61-3708. NO CRACKS NOTED.