What was found
CARGO COMPARTMENT BETWEEN FS 559 + 80 AND FS 574.00, RBL 43.00 FLOOR SUPPORT STRUCTURE UPPER SURFACE AROUND FASTENER HOLES HAS CORROSION. REMOVED CORROSION ON FLOOR SILL IAW SRM CH 51-21-06. PERFORMED UT THICKNESS INSP OF BLEND AREAS IAW MAC NAT INSP PROCEDURE UT-3 MINIMUM THICKNESS REMAINING IS .056". PERFORMED EDDY CURRENT INSP IAW NDTM 51-20-06 AND REO 601R-53-121. NO CRACKS NOTED.