As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CARGO COMPARTMENT BETWEEN FS 559 + 80 AND FS 559 + 112 LBL 43.00 FLOOR SUPPORT STRUCTURE UPPER SURFACE AROUND FASTENER HOLES HAS CORROSION. BLENDED CORROSION ON FLOOR SILL IAW SRM 51-21-06. PERFORMED UT THICKNESS INSP OF BLEND AREAS ON LT FLOOR SILL IAW MAC NDT INSP PROCEDURE UT-3 MINIMUM THICKNESS REMAINING OS .061". COMPLIED WITH STEP 3 OF REO 601R-53-51-120 IAW NDTM PART 1, 51-20-06. NO INDICATIONS NOTED. COMPLIED WITH STEPS 4 AND 5 OF REO 601R-53-51-120.