As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND PAX DOOR AFT WEB CRACKED APPROX .300" L STARTING AT EDGE OF WEB AND FOUND 3 DRILL STARTS ON DOOR STRUCTURE WHILE PERFORMING REO 601R-52-11-1842. REPAIRED PAX DOOR AFT WEB IAW REO 601R-52-11-1844 STEPS 1-3, 5-24. COMPLIED WITH STEP 4 OF REO 601R-52-11-1844A. PERFORMED EDDY CURRENT. NO INDICATIONS NOTED. COMPLIED WITH ASA ECTC REO 601R-52-11-1844.