What was found
SUPPORT CLIP CRACKED AT UPPER, OTBD FASTENER AREA AT FS 484, LBL 36 AND CROSS SUPPORT BEAM, PREVIOUSLY REPAIRED. STEPS 1 & 2 HAVE BEEN PREVIOUSLY REPAIRED AND FOUND TO BE IN SERVICEABLE CONDITION IAW REO 601R-53-41-059. CUT EDGE REQUIRE NDI. COMPLIED WITH STEP REO 601R-53-41-059B PERFORMED EDDY CURRINT OF LBL 36, FS 484 IAW NDTM 51-20-06. NO INDICATONS NOTED AT THIS TIME. FABRICATED REPAIR ANGLE IAW STEP 5/13/6 OF REO 601R-53-41-059. ANGLE REQUIRES NDI. COMPLIED WITH STEP 13 OF REO 601R-53-1-059B. PERFORMED EDDY CURRENT OF FABRICATED ANGLE IAW NDTM 51-20-06. NO INDICATIONS NOTED AT THIS TIME. REQUIRES ANGLE TO BE PAINTED AND INSTALLED. REMOVED CRACKED ANGLE AND INSTALLED NEW ANGLE IAW STEPS 8-14 OF REO 601R-53-41-059. EC/TC REQUIRED.