What was found
FLOOR SUPPORT HAS MINOR CORROSION AROUND NUTPLATES ON INBD ROW OF CARGO FLOOR PANEL 281LLF. REMOVED NUT PLATES ON FLOOR SUPPORT CAP AT LBL 27 STA 585-615 BLENDED CORRODED AREAS ON LBL 27 FLOOR SUPPORT CAP AT STA 615, 609, 603, 597, 591, 585 REF SEM 51-21-06. PERFORMED UT THICKNESS INSP OF BLENDED AREAS ON FLOORBEAM CAP IAW MAC NDT INSP PROCEDURE UT-3 MINIMUM MATERIAL REMAINING IS FS 615-.060", FS 609-.039", FS 603-.045", FS 597 UNREADABLE, FS 591-.028", FS 585-.026". REMOVED FASTNERS FROM LT SIDE OF FLOOR SUPPORT CAP IAW SRM 51-42-06. BLENDED AREAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00- FIG 101.