What was found
INTERCOSTAL CRACKED AT RBL 36.0 & FS 484.0. COMPLIED WITH STEPS 1 & 2 OF REO 601R-53-41-059. PERFORMED EDDY CURRENT INSP ON CUTLINE EDGES OF INTERCOSTAL AT RBL 36.0 FS 484.0. NO INDICATIONS FOUND AT THIS TIME, REPORT ATTACHED IAW STEP 3 OF REO 601R-53-41-059 AND NDTM PART 51-20-06. TOUCH UP EDGES IS REQ'D. TOUCHED UP EDGES AS REQUIRED IAW STEP 4 OF REO 601R-53-41-059. COMPLIED WITH STEPS 5 THRU 14 OF REO 601R-53-41-059. REPAIR TO THE INTERCOSTALS AT FS 484 BETWEEN BL27.00 AND BL36.00 IS COMPLETED IAW REO 601R-53-41-059 AND MEETS WITH ALL THEIR REQUIREMENTS.