What was found
FS 364.00 JUST FWD OF AVIONICS CUTOUT FRAME HAS CORROSION FROM STR 25L TO STR 25R. REMOVED 7 FITTINGS AND 2 EA GUSSET PLATES IAW SRM 51-42-06, 51-42-21 AND 51-41-02 LOCATED AND DRILLED UP FRAME SECTION IAW SRM 51-42-06. INSTALLED NEW SERVICEABLE FRAME SECTION AND 2 EA GUSSET PLATES IAW SRM 51-42-06 AND 51-42-21. DOOR ADJUSTMENT AND PROX SYS CHECK DUE. C/W FUNC AND OPS CHECK IAW AMM 52-42-00-220-801 AND 52-70-08-710-801, CHECK GOOD.